1993 FORD F-350

Report Date:
February 04, 2008
Campaign Number:
08V051000
Component:
VEHICLE SPEED CONTROL:CRUISE CONTROL

Summary:
FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.

Consequence Summary:
AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.

Corrective Summary:
DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

1993 FORD F-350

Report Date:
August 03, 2007
Campaign Number:
07V336000
Component:
VEHICLE SPEED CONTROL

Summary:
ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Consequence Summary:
THIS COULD RESULT IN AN UNDERHOOD FIRE.

Corrective Summary:
DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.

1993 FORD F-350

Report Date:
May 24, 2006
Campaign Number:
06E049000
Component:
EXTERIOR LIGHTING

Summary:
CERTAIN CK MOTORSPORTS COMBINATION HEADLIGHTS, CLEAR CORNER, BUMPER, AND SIDE MARKER LIGHTS SOLD AS REPLACEMENT LAMPS FOR USE ON THE PASSENGER VEHICLES LISTED ABOVE. SOME COMBINATION LAMPS THAT ARE NOT EQUIPPED WITH AMBER SIDE REFLECTORS FAIL TO CONFORM TO FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 108, LAMPS, REFLECTIVE DEVICES, AND ASSOCIATED EQUIPMENT.

Consequence Summary:
WITHOUT THE AMBER REFLECTORS, THE VEHICLE WILL BE POORLY ILLUMINATED, POSSIBLY RESULTING IN A VEHICLE CRASH WITHOUT WARNING.

Corrective Summary:
CK MOTORSPORT WILL NOTIFY OWNERS AND REPLACE THE NONCOMPLIANT LAMPS FREE OF CHARGE. THE RECALL BEGAN ON JULY 1, 2006. OWNERS MAY CONTACT CK MOTORSPORT AT 1-909-610-7211.

1993 FORD F-350

Report Date:
July 19, 2001
Campaign Number:
01I008000
Component:
FUEL SYSTEM, GASOLINE

Summary:
THIS IS NOT A SAFETY RECALL IN ACCORDANCE WITH THE SAFETY ACT. HOWEVER, IT IS DEEMED A SAFETY IMPROVEMENT CAMPAIGN BY THE AGENCY. VEHICLE DESCRIPTION: 1990-1993 FORD F-SERIES VEHICLES EQUIPPED WITH DUAL FUEL TANKS AND 4.9, 5.0,5.8, OR 7.5 LITER GASOLINE FUELED ENGINES. SOME VEHICLES CAN EXPERIENCE A CROSS TANK FUEL FLOW CONDITION DUE TO A DAMAGED CHECK VALVE IN THE FUEL PUMP/SENDER ASSEMBLY. FUEL MAY BE SUPPLIED FROM ONE TANK AND SOME OR ALL OF THE UNUSED FUEL MAY BE RETURNED TO THE OTHER TANK.

Consequence Summary:
SHOULD THIS OCCUR, THE CAPACITY OF THE RECEIVING TANK MAY BE EXCEEDED AND FUEL MAY OVERFLOW FROM THE FILLER CAP.

Corrective Summary:
FORD IS EXTENDING THE WARRANTY FOR POTENTIAL FUEL CROSS-FLOW TO 12 YEARS OF SERVICE OR 150,000 MILES FROM THE VEHICLE'S WARRANTY START DATE, WHICHEVER OCCURS FIRST. THIS COVER WILL AUTOMATICALLY TRANSFER TO SUBSEQUENT OWNERS AT NO CHARGE. IF A VEHICLE ALREADY HAS MORE THAN 150,000 MILES, THIS OVERAGE WILL LAST UNTIL DECEMBER 31, 2001. IF THE VEHICLE IS EXPERIENCING A FUEL CROSS-FLOW CONDITION, DEALERS WILL REPAIR THE CONDITION FREE OF CHARGE.

1993 FORD F-350

Report Date:
May 22, 2001
Campaign Number:
01X001000
Component:
TIRES:TREAD/BELT

Summary:
THIS IS NOT A SAFETY RECALL IN ACCORDANCE WITH THE SAFETY ACT. HOWEVER, IT IS DEEMED A SAFETY IMPROVEMENT CAMPAIGN BY THE AGENCY. EQUIPMENT DESCRIPTION: FORD IS REPLACING ALL FIRESTONE WILDERNESS AT 15, 16, AND 17 INCH TIRES MOUNTED ON FORD TRUCKS AND SUVS. FORD REPORTS TREAD SEPARATION CAN OCCUR DUE TO A COMBINATION OF THE SENSITIVITY OF THE TIRE DESIGN TO STRESS, AGING, AND MANUFACTURING DIFFERENCES BETWEEN PLANTS. FORD IS REPLACING THESE TIRES TO PREVENT POSSIBLE PREMATURE TIRE FAILURE. VEHICLE DESCRIPTION: THE VEHICLES LISTED BELOW MAY HAVE BEEN ORIGINALLY EQUIPPED WITH FIRESTONE WILDERNESS AT TIRES OR MAY HAVE HAD WILDERNESS AT TIRES INSTALLED DURING THE FIRESTONE RECALL LAUNCHED IN AUGUST 2000. CERTAIN 1991 THROUGHT 2002 FORD EXPLORER CERTAIN 2001 THROUGHT 2002 EXPLORER SPORT, AND SPORT TRAC CERTAIN 1997 THROUGH 2002 MERCURY MOUNTAINEER CERTAIN 1991 THROUGH 2001 RANGER CERTAIN 1999 THROUGH 2001 EXPEDITION CERTAIN 1991 THROUGH 1994, AND 1997 MODEL YEAR F-SERIES CERTAIN 1991 THROUGH 1994 BRONCO NOTE: BOTH ORIGINAL EQUIPMENT AND REPLACEMENT TIRES ARE AFFECTED.

Consequence Summary:
SHOULD THE TREAD SEPARATE AT HIGHWAY SPEEDS, A VEHICLE CRASH COULD OCCUR, POSSIBLY RESULTING IN PERSONAL INJURY OR DEATH.

Corrective Summary:
THE REPLACEMENT/REIMBURSEMENT PROGRAM FOR THIS CAMPAIGN EXPIRED ON MARCH 31, 2002. HOWEVER, CUSTOMERS CAN CONTACT FORD AT 1-877-917-3673 OR GO ON-LINE TO WWW.FORD.COM FOR POSSIBLE ASSISTANCE.

1993 FORD F-350

Report Date:
December 29, 2000
Campaign Number:
00V424000
Component:
FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY

Summary:
VEHICLE DESCRIPTION: LIGHT DUTY TRUCKS AND CAB CHASSIS EQUIPPED WITH GASOLINE ENGINES AND DUAL FUEL TANKS. THE CARBON STEEL FUEL PRESSURE REGULATOR IN THE FUEL SYSTEM CAN WEAR OUT DURING THE LIFE OF THE VEHICLE. IF THE FUEL PRESSURE REGULATOR MALFUNCTIONS, IT CAN CAUSE HIGH FUEL SYSTEM PRESSURE, WHICH DAMAGES THE FUEL PUMP CHECK VALVE. THIS ALLOWS FUEL TO BE TRANSFERRED FROM ONE TANK TO THE OTHER, POSSIBLY OVERFILLING THE NON-OPERATING TANK, RESULTING IN FUEL OVERFLOW PAST THE FILLER CAP.

Consequence Summary:
FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A VEHICLE FIRE.

Corrective Summary:
DEALERS WILL HAVE A STAINLESS STEEL FUEL PRESSURE REGULATOR INSTALLED. OWNER NOTIFICATION BEGAN JULY 9, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332. (SEE PREVIOUS NHTSA RECALL 93V-125/FORD RECALL 93S68).

1993 FORD F-350

Report Date:
September 07, 1994
Campaign Number:
94V169001
Component:
PARKING BRAKE:CONVENTIONAL

Summary:
THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.

Consequence Summary:
WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.

Corrective Summary:
A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.

1993 FORD F-350

Report Date:
January 02, 1994
Campaign Number:
94V018000
Component:
STRUCTURE:BODY:BUMPERS

Summary:
THE U-CLIP STYLE NUTS THAT RETAIN THE FRONT BUMPERS TO THE FRONT BUMPER INNER ARMS CAN FRACTURE.

Consequence Summary:
IF ONE OF THE U-CLIP NUTS FRACTURES, THE BUMPER WILL LOOSEN AND RATTLE CAUSING FRACTURE OF THE REMAINING U-CLIP NUTS, RESULTING IN SEPARATION OF THE BUMPER FROM THE VEHICLE. IF THE BUMPER WERE TO DETACH FROM THE VEHICLE WHILE IT IS BEING DRIVEN, A VEHICLE COLLISION COULD RESULT.

Corrective Summary:
INSPECTION AND REPLACEMENT OF THE FOUR U-CLIP NUTS AND THE ASSOCIATED BOLTS.

1993 FORD F-350

Report Date:
August 02, 1993
Campaign Number:
93V125000
Component:
FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY

Summary:
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence Summary:
SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Corrective Summary:
REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.